Electrical data
Primary nominal
Primary current
Primary
Type
r.m.s. current
measuring range
conductor
I
PN (A)
I
P (A)
(mm)
50
± 150
1.6 x 3.5
HY 50-P/SP1
V
C
Supply voltage (± 5 %)
single + 5
V DC
I
C
Current consumption
10
mA
Î
P
Overload capability (1 ms)
50 x I
PN
V
d
R.m.s. voltage for AC isolation test, 50/60Hz, 1 min
2.5
kV
V
b
R.m.s. rated voltage,safe separation
5001)
V
R
IS
Isolation resistance @ 500 VDC
> 1000
M
V
OUT
Output voltage @ + I
PN, RL = 10 kΩ, TA = 25°C
2.5
V
Output voltage @ - I
PN, RL = 10 kΩ, TA = 25°C
1.5
V
R
OUT
Output internal resistance
100
R
L
Load resistance
> 1
k
Accuracy - Dynamic performance data
X
Accuracy @ I
PN, TA = 25°C (without offset)
< ± 2
%
εεεεε
L
Linearity 2) (0 .. ± I
PN)
< ± 1
% of I
PN
V
OE
Electrical offset voltage, T
A = 25°C
< + 2V ± 25 mV
V
OH
Hysteresis offset voltage @ I
P = 0
after an excursion of 1 x I
PN
< ± 10
mV
V
OT
Thermal drift of V
OE
typ
± 1.5
mV/K
max
± 3
mV/K
TC
εεεεε
G
Thermal drift of the gain (% of reading)
< ± 0.1
%/K
t
r
Response time @ 90% of I
P
< 5
µs
di/dt
di/dt accurately followed
> 50
A/µs
f
Frequency bandwidth 3) (0 .. - 3 dB)
DC .. 50
kHz
General data
T
A
Ambient operating temperature
- 10 .. + 80
°C
T
S
Ambient storage temperature
- 25 .. + 85
°C
m
Mass
< 14
g
Standards 4)
EN50178
Current Transducers, HY 50-P/SP1
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
PN
=
50 A
Notes : 1) Pollution class 2, overvoltage category III
2) Linearity data exclude the electrical offset.
3) Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency
4) Please consult characterisation report for more techinical details and
application advises.
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 2500 V~
Compact design for PCB mounting
Low power consumption
Extended measuring range (3 x I
PN)
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Easy mounting
Small size and space savings
Only one design for wide current
ratings range
High immunity against external
interference
Applications
General purpose inverters
Switched-Mode Power Supplies
(SMPS)
AC motor speed control
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Power supplies for welding
applications.
980723/2
LEM Components
www.lem.com




HTML 页

1  2 


数据表 下载




链接网址


Privacy Policy
ALLDATASHEETCN.COM
ALLDATASHEET是否为您带来帮助?  [ DONATE ]  

关于 Alldatasheet    |   广告服务   |   联系我们   |   隐私政策   |   书签   |   链接交换   |   制造商名单
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  , Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp  |   Russian : Alldatasheetru.com
Korean : Alldatasheet.co.kr   |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com  |   Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl