数据搜索系统,热门电子元器件搜索
  Chinese  ▼

Delete All
ON OFF
ALLDATASHEETCN.COM

X  

预览 PDF Download HTML

CT5-T 数据表(PDF) 1 Page - LEM

部件名 CT5-T
功能描述  Current Transducers CT 5-T
Download  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  LEM [LEM]
网页  http://www.lem.co.jp/HQ/en
标志 LEM - LEM

CT5-T 数据表(HTML) 1 Page - LEM

  CT5-T Datasheet HTML 1Page - LEM CT5-T Datasheet HTML 2Page - LEM  
Zoom Inzoom in Zoom Outzoom out
 1 / 2 page
background image
Current Transducer CT 5-T
For very accurate measurements of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
I
P N
Primary nominal r.m.s. current
5
A
I
P
Primary current, measuring range
0 .. ± 7.5
A
V
OU T
Analog output voltage
5
V
K
N
Conversion ratio
5 A / 5 V
R
L
Load resistance
> 500
C
L
Capacitance loading
≤ 5
nF
t
C
Output short-circuit duration 1)
s
V
C
Supply voltage (± 5 %)
± 15
V
I
C
Current consumption
90 + V
OUT / RL
mA
V
d
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
6
kV
Accuracy - Dynamic performance data
X
G
Overall accuracy @ I
PN
- 25°C .. + 70°C
± 0.1
%
Typ
Max
V
O
Offset voltage @ I
P = 0
T
A = 25°C
± 0.4
mV
- 25°C .. + 70°C
± 0.6
mV
f
Frequency bandwidth (- 3 dB) @ 10 % of I
PN
DC .. 500
kHz
General data
T
A
Ambient operating temperature
- 25 .. + 70
°C
T
S
Ambient storage temperature
- 40 .. + 85
°C
m
Mass
670
g
Standards 2)
EN 50178
Notes : 1) If the short-circuit has a duration more than 1 s, the primary current of
the supply voltage must be interrupted for a short time to restore the
transducer to proper working order. The internal protection is done by
PTC resistors
2) A list of corresponding tests is available
Features
Closed loop (compensated) current
transducer
Insulated plastic case recognized
according to UL 94-V0
Patent pending.
Advanced features
f = 500 kHz
X
G =
± 0.1 % (- 25°C .. + 70°C).
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
I
PN
=
5 A
980814/5
LEM Components
ww w .lem.com


Html Pages

1  2 


数据表 下载

Go To PDF Page


链接网址




隐私政策
ALLDATASHEETCN.COM
ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn