3 / 8 page ③ 2.3 PS-ON Remote On/Off Control: When PS-ON is pulled to TTL Low, the DC output is to be enabled. When PS-OFF is pulled to TTL high, the DC output is to be disabled. 2.4 PW-OK PW-OK is power good signal and should be asserted high by the power supply to indicate that +5VDC and +3.3VDC output are above the under voltage thresholds of the power supply TTL. compatible signal out with 100ms to 500ms. Timing of PS-ON, PW-OK, and Germane Voltage Rails Although there is no requirement to meet specific timing parameters, The following signal timings are recommended: 2ms≦T2≦200ms 100ms≦T3≦500ms T4>1ms T5≦10ms 2.5 Efficiency: ≧ 73﹪at full load. (Normal Line) 2.6 Hold-Up Time: 16ms at maximum load & normal input voltage. 3. PROTECTIONS 3.1 OVER-VOLTAGE PROTECTION Standard on +5.0V output, set at 6.25VDC ± 075VDC. 3.2 SHORT CIRCUIT PROTECTION A short circuit placed between the DC Return and the output shall cause No damage and the power supply shall shutdown. |
类似零件编号 - TC-300R2UH |
|
类似说明 - TC-300R2UH |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |