数据搜索系统,热门电子元器件搜索 |
|
LTC1098LCS8 数据表(PDF) 3 Page - Linear Technology |
|
LTC1098LCS8 数据表(HTML) 3 Page - Linear Technology |
3 / 28 page 3 LTC1096/LTC1096L LTC1098/LTC1098L RECO E DED OPERATI G CO DITIO S SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS VCC Supply Voltage 2.65 4.0 V fCLK Clock Frequency VCC = 2.65V 25 250 kHz tCYC Total Cycle Time LTC1096L, fCLK = 250kHz 58 µs LTC1098L, fCLK = 250kHz 58 µs thDI Hold Time, DIN After CLK ↑ VCC = 2.65V 450 ns tsuCS Setup Time CS ↓ Before First CLK↑ (See Operating Sequence) VCC = 2.65V, LTC1096L 1 µs VCC = 2.65V, LTC1098L 1 µs tWAKEUP Wake-Up Time CS ↓ Before First CLK↓ After First CLK↑ VCC = 2.65V, LTC1096L 10 µs (See Figure 1, LTC1096L Operating Sequence) Wake-Up Time CS ↓ Before MSBF Bit CLK↓ VCC = 2.65V, LTC1098L 10 µs (See Figure 2, LTC1098L Operating Sequence) tsuDI Setup Time, DIN Stable Before CLK↑ VCC = 2.65V 1 µs tWHCLK CLK High Time VCC = 2.65V 1.6 µs tWLCLK CLK Low Time VCC = 2.65V 1.6 µs tWHCS CS High Time Between Data Transfer Cycles VCC = 2.65V 2 µs tWLCS CS Low Time During Data Transfer LTC1096L, fCLK = 250kHz 56 µs LTC1098L, fCLK = 250kHz 56 µs LTC1096/LTC1098 SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS tWLCLK CLK Low Time VCC = 5V 0.8 µs tWHCS CS High Time Between Data Transfer Cycles VCC = 5V 1 µs tWLCS CS Low Time During Data Transfer LTC1096, fCLK = 500kHz 28 µs LTC1098, fCLK = 500kHz 28 µs VCC = 3V Operation fCLK Clock Frequency VCC = 3V 25 250 kHz tCYC Total Cycle Time LTC1096, fCLK = 250kHz 58 µs LTC1098, fCLK = 250kHz 58 µs thDI Hold Time, DIN After CLK ↑ VCC = 3V 450 ns tsuCS Setup Time CS ↓ Before First CLK↑ (See Operating Sequence) VCC = 3V, LTC1096 1 µs VCC = 3V, LTC1098 1 µs tWAKEUP Wake-Up Time CS ↓ Before First CLK↓ After First CLK↑ VCC = 3V, LTC1096 10 µs (See Figure 1 LTC1096 Operating Sequence) Wake-Up Time CS ↓ Before MSBF Bit CLK↓ VCC = 3V, LTC1098 10 µs (See Figure 2 LTC1098 Operating Sequence) tsuDI Setup Time, DIN Stable Before CLK↑ VCC = 3V 1 µs tWHCLK CLK High Time VCC = 3V 1.6 µs tWLCLK CLK Low Time VCC = 3V 1.6 µs tWHCS CS High Time Between Data Transfer Cycles VCC = 3V 2 µs tWLCS CS Low Time During Data Transfer LTC1096, fCLK = 250kHz 56 µs LTC1098, fCLK = 250kHz 56 µs LTC1096L/LTC1098L |
类似零件编号 - LTC1098LCS8 |
|
类似说明 - LTC1098LCS8 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |