数据搜索系统,热门电子元器件搜索 |
|
HMA423R409T 数据表(PDF) 5 Page - International Rectifier |
|
HMA423R409T 数据表(HTML) 5 Page - International Rectifier |
5 / 8 page www.irf.com 5 HMA423R409T/ES Notes. Electrical Performance Characteristics 1) Parameter is tested as part of design characterization or after design changes. Thereafter, parameter shall be guaranteed to the limits specified. 2) Parameter verified during line and load regulation tests. 3) Although operation with no load is permissible, light loading on the main (+3.4V) output may cause the output voltage of the auxiliary outputs (±9.2V) to drop out of regulation. It is therefore recommended that at least 450 mA or 10 percent of the total output power, whichever is greater, be taken from the main (+3.4V) output. 4) Although operation with no load is permissible, heavy loading on the main (+3.4V) output may cause the output voltage of the auxiliary outputs (±9.2V) to rise out of regulation. It is therefore recommended that at least 20 percent of the total output power, whichever is greater, be taken from the auxiliary (±9.2V) outputs. 5) Unless otherwise specified, “Rated” load is 15.3W on the main (+3.4V) output, 21.16W on the +9.2V output and 10.58W on the -9.2V output. Load currents of up to 6.0A on the 3.4V output, 2.3A on the +9.2V and 1.15A on the -9.2V output are acceptable as long as the total output power does not to exceed 50W. 6) Guaranteed for a D.C. to 20MHz bandwidth. Tested using a 20KHz to 10MHz bandwidth using the circuit shown on next page. 7) Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum limit may interfere with the proper operation of the converter’s overload protection, causing erratic behavior during turn-on. 8) Overload power dissipation is defined as the device power dissipation with the load set such that V OUT = 90% of nominal. 9) Load step transition time ≤ 10 µsec. 10) Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1% of its steady state value. 11) The worst case loading condition is min load on the main (+3.4V) output and max load on the auxiliary (±9.2V) outputs. In this case, the ±9.2V output can be drop down to 7.9V. 12) Turn-on delay time from either a step application of input power or a logic low to a logic high transition on the inhibit pin (pin 3) to the point where V OUT = 90% of nominal. 13) Load is varied for output under test while the remaining outputs are loaded at 50% of rated. Regulation relative to output voltage at 50% rated load. |
类似零件编号 - HMA423R409T |
|
类似说明 - HMA423R409T |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |