数据搜索系统,热门电子元器件搜索 |
|
1SVR740750R0400 数据表(PDF) 9 Page - List of Unclassifed Manufacturers |
|
1SVR740750R0400 数据表(HTML) 9 Page - List of Unclassifed Manufacturers |
9 / 18 page Data sheet | Voltage monitoring relay CM-EFS.2 - 9 Voltage window monitoring 2x1 c/o (SPDT) contact i OFF-delayed B without latching e Open-circuit principle h The voltage to be monitored (measured value) is applied to terminals B-C. The control supply voltage applied to terminals A1-A2 is displayed by the glowing green LED. If the measured value exceeds the threshold valuemax (>U) or drops below the threshold valuemin (<U), the output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, energizes, the yellow LED (relays energized) glows and the red LED glows (overvoltage), or flashes W (undervoltage) respectively. If the measured value decreases below the threshold valuemax minus the fixed hysteresis (5 %) or exceeds the threshold valuemin plus the fixed hysteresis (5 %), the tripping delay TV starts and the red LED turns off. Timing of TV is displayed by the flashing W green LED. When TV is complete, the output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, de-energizes and the yellow LED (relay energized) turns off. If control supply voltage is interrupted, the green LED turns off. Closed-circuit principle g The voltage to be monitored (measured value) is applied to terminals B-C. When control supply voltage is applied to terminals A1-A2, the output relays energize and the green and yellow LED (relays energized) glow. If the measured value exceeds the threshold valuemax (>U) or drops below the threshold valuemin (<U), the output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, de-energizes, the yellow LED turns off and the red LED glows (overvoltage), or flashes W (undervoltage) respectively. If the measured value decreases below the threshold valuemax minus the fixed hysteresis (5 %) or exceeds the threshold valuemin plus the fixed hysteresis (5 %), the tripping delay TV starts and the red LED turns off. Timing of TV is displayed by the flashing W green LED. When TV is complete, the output relay 1115-1216/1418 (>U), or 2125-2226/2428 (<U) respectively, energizes and the yellow LED (relay energized) glows. If control supply voltage is interrupted, the output relays de-energize and the yellow and green LEDs turn off. A1-A2 >U: 11-14 (15-18) 11-12 (15-16) <U: 21-24 (25-28) 21-22 (25-26) >U: 11-14 (15-18) 11-12 (15-16) <U: 21-24 (25-28) 21-22 (25-26) closed open Thresholdmax Hysteresis green LED red LED yellow LED green LED red LED yellow LED Open-circuit principle Closed-circuit principle TV TV Hysteresis Measured value Thresholdmin |
类似零件编号 - 1SVR740750R0400 |
|
类似说明 - 1SVR740750R0400 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |