数据搜索系统,热门电子元器件搜索 |
|
D4DL-2DFA-B 数据表(PDF) 4 Page - Omron Electronics LLC |
|
D4DL-2DFA-B 数据表(HTML) 4 Page - Omron Electronics LLC |
4 / 18 page G-156 Safety Sensors / Components Characteristics Note: 1. The above values are initial values. 2. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi- cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NL in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or mal- functioning may occur. 3. The durability is for an ambient temperature of 5 ° C to 35° C and an ambient humidity of 40% to 70%. For more details, consult your OM- RON representative. 4. If the ambient temperature is greater than 35 ° C, do not pass the 3-A, 250-VAC load through more than 2 circuits. 5. These figures are minimum requirements for safe operation. 6. This figure is based on the GS-ET-19 evaluation method. 7. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. Degree of protection (see note 2) IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is IP00.) Durability (see note 3) Mechanical 1,000,000 operations min. Electrical 500,000 operations min. for a resistive load of 3 A at 250 VAC (see note 4) Operating speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Rated frequency 50/60 Hz Contact gap 2 x 2 mm min Direct opening force (see note 5) 60 N min. (EN60947-5-1) Direct opening travel (see note 5) 10 mm min. (EN60947-5-1) Holding force (see note 6) 1,300 N min. Insulation resistance 100 M Ω min. (at 500 VDC) Minimum applicable load (see note 7) Resistive load of 1 mA at 5 VDC (N-level reference value) Rated insulation voltage (U i) 300 V (EN60947-5-1) Rated open thermal current (I th) 10 A (EN60947-5-1) Impulse withstand voltage (EN60947-5-1) Between terminals of the same polarity 2.5 kV Between terminals of different polarities 4 kV Between other terminals and uncharged metallic parts 6 kV Conditional short-circuit current 100 A (EN60947-5-1) Pollution degree (operating environment) 3 (EN60947-5-1) Protection against electric shock Class II (double insulation) Contact resistance 25 m Ω max. per contact (initial value) Vibration resis- tance Malfunction 10 to 55 Hz, 0.75-mm single amplitude Shock resistance Destruction 1,000 m/s2 min. Malfunction 300 m/s2 min. (100 m/s2 min. for the lock monitor switch) Ambient temperature Operating: −10° C to 55° C with no icing Ambient humidity Operating:95% max. Weight Approx. 370 g (D4NL-IAFA-B) F502-EN2-04.book Seite 156 Dienstag, 26. Juli 2005 5:48 17 |
类似零件编号 - D4DL-2DFA-B |
|
类似说明 - D4DL-2DFA-B |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |