数据搜索系统,热门电子元器件搜索 |
|
SS8039H463TCTR 数据表(PDF) 5 Page - Silicon Standard Corp. |
|
SS8039H463TCTR 数据表(HTML) 5 Page - Silicon Standard Corp. |
5 / 7 page SS8039 www.SiliconStandard.com 5 of 7 Rev.2.02 1/06/2004 Pin Description PIN NAME FUNCTION 1 GND Ground RESET (SS8039L) RESET Output remains low while VCC is below the reset threshold, and for at least 140ms after VCC rises above the reset threshold. 2 RESET (SS8039H) RESET Output remains high while V CC is below the reset threshold, and for at least 140ms after VCC rises above the reset threshold. 3 MR Manual Reset Input. A logic low on MR asserts reset. Reset remains asserted as long as MR is low and for at least 140ms after MR returns high, This active-low input has an internal 20kΩ pull- up resistor. It can be driven from a TTL or CMOS-logic line, or shorted to ground with a switch. Leave open if unused. 4 VCC Supply Voltage (+5V, +3.3V, +3.0V) Detailed Description A microprocessor’s (µP’s) reset input starts the µP in a known state. The SS8039L and SS8039H assert reset to prevent code-execution errors during power-up, power-down, or brownout conditions. They assert a reset signal whenever the VCC supply voltage declines below a preset threshold, keeping it asserted for at least 140ms after VCC has risen above the reset threshold. The SS8039L/SS8039H have a push-pull output stage. The manual reset input (MR) can also initiate a reset. See the Manual Reset Input Section. Manual Reset Input Fig.1 Maximum Transient Duration Without Many µP-based products require manual reset capability Causing a Reset Pulse vs. Reset Comparator Overdrive allowing the operator, a test technician, or external logic circuitry to initiate a reset. A logic low on MR asserts reset. Reset remains asserted while MR is low, and for the Reset Active Timeout Period (t RP) after MR returns high. This input has an internal 20k Ω pull-up resistor, so it can be left open if it is not used. MR can be driven with TTL or CMOS-logic levels, or with open-drain / collector outputs. Connect a normally open momentary switch from MR to GND to create a manual-reset function; external debounce circuitry is not required. If MR is driven from long cables or if the device is used in a noisy environment, connecting a 0.1µF capacitor from MR to ground provides additional noise immunity. Figure2. RESET Valid to VCC = Ground Circuit V CC RESET GND R1 100k V CC RESET GND SS8039 R1 100k 0 100 200 300 400 500 600 1 10 100 1000 Reset Comparator Overdrive, V TH-VCC (mV) |
类似零件编号 - SS8039H463TCTR |
|
类似说明 - SS8039H463TCTR |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |