数据搜索系统,热门电子元器件搜索 |
|
SS-01GPD 数据表(PDF) 5 Page - Omron Electronics LLC |
|
SS-01GPD 数据表(HTML) 5 Page - Omron Electronics LLC |
5 / 8 page Subminiature Basic Switch SS-P 107 Precautions ■ Correct Use Mounting Mount the Switch onto a flat surface. Mounting on an uneven surface may cause deformation of the Switch, resulting in faulty operation or breakage in the housing. Operating Stroke Setting Take particular care in setting the operating stroke for the pin plunger models. Make sure that the operating stroke is 60% to 90% of the rated OT distance. Do not operate the actuator exceeding the OT dis- tance, otherwise the life expectancy of the Switch may be shortened. Using Microloads Using a model for ordinary loads to switch microloads may result in faulty operation. Instead, use the models that are designed for micro- loads and that operate in the following range; However, even when using microload models within the operating range shown above, if inrush current or inductive voltage spikes occur when the contact is opened or closed, it may increase contact wear and so decrease the service life. Therefore, insert a contact protection circuit where necessary. ■ Cautions Handling Turn OFF the power supply before mounting or removing the Switch, wiring, or performing maintenance or inspection. Failure to do so may result in electric shock or burning. Solder Terminal Connection When soldering lead wires to solder terminals, first insert the lead wire conductor through the terminal hole and then solder. Make sure that the temperature at the tip of the soldering iron is 350 to 400 °C. Do not take more than 3 seconds to solder the switch terminal, and do not impose external force on the terminal for 1 min after soldering. Improper soldering involving an excessively high temperature or excessive soldering time may deteriorate the charac- teristics of the Switch. Quick-Connect Terminals Wire quick-connect terminals (#110) with receptacles. Insert the ter- minals straight into the receptacles. Do not impose excessive force on the terminal in the horizontal direction, otherwise the terminal may be deformed or the housing may be damaged. Use appropriate #110 QC connectors, made by Nippon Tanshi or Tyco Electronics, to mate with the quick-connect versions of the switch. These connectors are not sold by OMRON. Contact Nippon Tanshi or Tyco Electronics to purchase these connectors. PCB Terminal Connection When using automatic soldering baths, we recommend soldering at 260 ±5°C within 5 seconds. Make sure that the liquid surface of the solder does not flow over the edge of the board. When soldering by hand, as a guideline, solder with a soldering iron with a tip temperature of 350 to 400 °C within 3 seconds, and do not apply any external force for at least 1 minutes after soldering. When applying solder, keep the solder away from the case of the Switch and do not allow solder or flux to enter the case. Insulation Distance Use a separator between the switch and metal mounting panels, to ensure proper dielectric characteristics are achieved. 30 24 12 5 0 1 10 100 1,000 Current (mA) 0.1 1 mA Operating range for general- load models SS-3P Operating range for micro load models SS-01P 26 mA 0.16 mA 100 mA 160 mA Inoperable range 100 mA |
类似零件编号 - SS-01GPD |
|
类似说明 - SS-01GPD |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |