1 / 1 page
ACITY VS. CURRENT
CAP
-30°C
0°C
25°C
55°C
72°C
0.01
0.1
1
0.20
0.25
0.30
0.35
0.40
mA
Ah
VOLTAGE VS. TEMPERATURE
1 mA
0.5 mA
0.1 mA
50
µA
10
µA
5
µA
3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.7
-50
-30
-10
10
30
50
70
ºC
Volts
DISCHARGE CHARACTERISTICS @ +25ºC
3.6 K
Ω
~1 mA
(0.38 Ah)
6.8 K
Ω
~0.5 mA
(0.42 Ah)
36
ΚΩ
~0.1 mA
(0.4 Ah)
75
ΚΩ
~50
µA
(0.39 Ah)
680
ΚΩ
~5
µA
(0.37 Ah)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1
10
100
1000
10000
100000
Hours
Volts
XOL - Extended Operating Life
ADDITIONAL INFORMATION
SUFFIX- /P
TIN PLATED NICKEL PINS
CATALOGUE NO.:
15-4986-43000
Nominal capacity @ 0.5 mA, to 2V
0.42 Ah
Rated voltage
3.6 V
Maximum recommended continuous current
5 mA
Maximum 1 sec. pulse capability
10 mA
Weight
5.7g (0.201 oz)
Volume
1.35 cc
Operating temperature range
-55ºC to +85ºC
U.L. Component Recognition MH 12193
MODEL TL-4986
International size reference: ER22G75
TECHNICAL DATA
(Typical values @+25ºC for batteries stored for one year or less)
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
Rev. D 05/03