6.2 Mechanical
Item
Te s t C o n d i t i o n s
Require me n t s
6.2.1.
Actuating
Force
Placing the switch such that the direction of switch
operation is vertical and then gradually increasing the
load applied to the center of the stem, the maximum
load required for the stem to come to a stop shall be
measured.
160
± 50
g f
OR
250
± 50
g f
6.2.2.
Travel
Placing the switch such that the direction of switch
operation is vertical and then applying a static load
twice the actuating force to the center of the stem, the
travel distance for the stem to come to a stop shall be
measured.
0.3
± 0.15 m m
6.2.3.
Return
Force
The sample switch is installed such that the direction
of switch operation is vertical and, upon depression of
the stem in its center the whole travel distance, the
force of the stem to return to its free position shall be
measured.
50
g f
min.
6.2.4.
Stop
Strength
Placing the switch such that the direction of switch
operation is vertical, a static load of
3
kgf shall be
applied in the direction of stem operation for a period
of
60
seconds.
There shall be no sign
of damage
mechanically
and electrically.
6.2.5
Stem
Strength
Placing the switch such that the direction of switch
operation is vertical, the maximum force to withstand
a pull applied opposite to the direction of stem
operation shall be measured.
3
k g f
PART NO:
TS6601H
3/6
TACTING
SWITCH
SPECIFICATION