SLAC Products
11
ABSOLUTE MAXIMUM RATINGS
Storage Temperature . . . . . . . . . –60°C < T
A < +125°C
Ambient Operating Temp . . . . . . . –40°C < T
A < +85°C
Ambient Relative Humidity . . . . . . . . . . . . 5% to 95%
(non condensing)
V
CCA with respect to VCCD . . . . . . . . . . . . . . . . ±50 mV
V
CCA with respect to AGND . . . . . . . . . –0.4 V to +7.0 V
V
CCD with respect to DGND . . . . . . . . –0.4 V to +7.0 V
AGND with respect to DGND . . . . . . . . . . . . . . ±0.4 V
I
IN Current
. . . . . . . . . . . . . . . . . . . . . . . . . . . ±10 mA
Other pins
with respect to DGND . . . . . .–0.4 V to V
CCD +0.4 V
Latch-up immunity (any pin). . . . . . . . . . . . . . ±30 mA
Stresses above those listed under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability.
OPERATING RANGES
V
CCA, Analog Supply . . . . . . . . . . . . . . . . VCCD ±10 mV
V
CCA, Analog Supply . . . . . . . . . . . . . +5.0 V ± 0.25 V
V
CCD, Digital Supply
. . . . . . . . . . . . . +5.0 V ± 0.25 V
DGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 V
AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mV
Ambient Temperature . . . . . . . . . . . .0°C < T
A < +70°C
Ambient Relative Humidity . . . . . . . . . . . .15% to 95%
Operating Ranges define those limits between which function-
ality of the device is guaranteed by 100% production testing.
Specifications in this data sheet are guaranteed by testing
from 0
°C to +70°C. Performance from –40°C to +85°C is
guaranteed by characterization and periodic sampling of pro-
duction units.