数据搜索系统,热门电子元器件搜索
Selected language     Chinese  ▼
部分名称
         详细搜索


ICE3BR4765JZ Datasheet(数据表) 17 Page - Infineon Technologies AG

部件型号  ICE3BR4765JZ
说明  Off-Line SMPS Current Mode Controller
下载  32 Pages
Scroll/Zoom Zoom In 100% Zoom Out
制造商  INFINEON [Infineon Technologies AG]
网页  http://www.infineon.com
标志 

 17 page
background image
ICE3BR4765JZ
Functional Description
Version 2.1
17
30 Aug 2011
3.7.3
Protection Modes
The IC provides Auto Restart Mode as the protection
feature. Auto Restart mode can prevent the SMPS from
destructive states. The following table shows the
relationship between possible system failures and the
corresponding protection modes.
Before entering the Auto Restart protection mode,
some of the protections can have extended blanking
time to delay the protection and some needs to fast
react and will go straight to the protection. Overload
and open loop protection are the one can have
extended blanking time while Vcc Overvoltage, Over
temperature, Vcc Undervoltage, short opto-coupler
and external auto restart enable will go to protection
right away.
After the system enters the Auto-restart mode, the IC
will be off. Since there is no more switching, the Vcc
voltage will drop. When it hits the Vcc turn off threshold,
the start up cell will turn on and the Vcc is charged by
the startup cell current to Vcc turn on threshold. The IC
is on and the startup cell will turn off. At this stage, it will
enter the startup phase (soft start) with switching
cycles. After the Start Up Phase, the fault condition is
checked. If the fault condition persists, the IC will go to
auto restart mode again. If, otherwise, the fault is
removed, normal operation is resumed.
3.7.3.1
Auto Restart mode with extended
blanking time
Figure 25
Auto Restart Mode
In case of Overload or Open Loop, the FB exceeds
4.0V which will be observed by comparator C4. Then
the internal blanking counter starts to count. When it
reaches 20ms, the switch S1 is released. Then the
clamped voltage 0.9V at VBA can increase. When there
is no external capacitor CBK connected, the VBA will
reach 4.0V immediately. When both the input signals at
AND gate G5 is positive, the Auto Restart Mode will be
activated after the extra spike blanking time of 30us is
elapsed. However, when an extra blanking time is
needed, it can be achieved by adding an external
capacitor, CBK. A constant current source of IBK will start
to charge the capacitor CBK from 0.9V to 4.0V after the
switch S1 is released. The charging time from 0.9V to
4.0V are the extendable blanking time. If CBK is 0.22uF
and IBK is 13uA, the extendable blanking time is around
52ms and the total blanking time is 72ms. In combining
the FB and blanking time, there is a blanking window
generated which prevents the system to enter Auto
Restart Mode due to large load jumps.
VCC Overvoltage
Auto Restart Mode
Overtemperature
Auto Restart Mode
Overload
Auto Restart Mode
Open Loop
Auto Restart Mode
VCC Undervoltage
Auto Restart Mode
Short Optocoupler
Auto Restart Mode
Auto restart enable
Auto Restart Mode
C3
4.0V
C4
4.0V
&
G5
0.9V
S1
1
G2
Control Unit
Auto
Restart
Mode
5.0V
BA
FB
C
BK
20ms
Blanking
Time
Spike
Blanking
30us
#
I
BK




HTML 页

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23  24  25  26  27  28  29  30  31  32 


数据表 下载




链接网址

ALLDATASHEET是否为您带来帮助?  [ DONATE ]  

关于 Alldatasheet    |   广告服务   |   联系我们   |   隐私政策   |   书签   |   链接交换   |   制造商名单
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  , Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp  |   Russian : Alldatasheetru.com
Korean : Alldatasheet.co.kr   |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com  |   Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl