6 / 73 page Data Sheet ADE9000 Rev. A | Page 5 of 72 Parameter Min Typ Max Unit Test Conditions/Comments Fundamental Apparent Energy 0.1 % Over a dynamic range of 5000 to 1, 2 sec accumulation 0.5 % Over a dynamic range of 10,000 to 1, 10 sec accumulation 0.1 % Over a dynamic range of 1000 to 1, 2 sec accumulation, PGA = 4, integrator on, HPF corner = 4.98 Hz 0.5 % Over a dynamic range of 5000 to 1, 10 sec accumulation, PGA = 4, integrator on, HPF corner = 4.98 Hz IRMS, VRMS 0.1 % Over a dynamic range of 1000 to 1 0.5 % Over a dynamic range of 5000 to 1 0.1 % Over a dynamic range of 500 to 1, PGA = 4, integrator on, HPF corner = 4.98 Hz 0.5 % Over a dynamic range of 1000 to 1, PGA = 4, integrator on, HPF corner = 4.98 Hz Fundamental IRMS, VRMS 0.1 % Over a dynamic range of 1000 to 1 0.5 % Over a dynamic range of 5000 to 1 0.1 % Over a dynamic range of 500 to 1, PGA = 4, integrator on, HPF corner = 4.98 Hz 0.5 % Over a dynamic range of 2000 to 1, PGA = 4, integrator on, HPF corner = 4.98 Hz Active Power, VAR, VA 0.2 % Over a dynamic range of 1000 to 1 0.4 % Over a dynamic range of, 3000 to 1 0.2 % Over a dynamic range of 500 to 1, PGA = 4, integrator on, HPF corner = 4.98 Hz 0.5 % Over a dynamic range of 1000 to 1, PGA = 4, integrator on, HPF corner = 4.98 Hz Power Factor (PF) Error ±0.001 % Over a dynamic range of 5000 to 1 128-Point per Line Cycle Resampled Data 0.1 % An FFT is performed to receive the magnitude response; this error is the worst case error in the magnitude caused by resampling algorithm distortion; input signal is 50 Hz fundamental and ninth harmonic both at half of full scale (FS) −72 dB Amplitude of highest spur; input signal is 50 Hz fundamental and ninth harmonic both at half of FS 1.25 % An FFT is performed to receive the magnitude response; this error is the worst case error in the magnitude caused by resampling algorithm distortion; input signal is 50 Hz fundamental and 31st harmonic, both at half of FS −38 dB Amplitude of highest spur; input signal is 50 Hz fundamental and 31st harmonic, both at half of FS VRMS½, IRMS½ RMS Voltage Refreshed Each Half-Cycle1 0.25 % Data sourced before HPF, no dc offset at inputs, over a dynamic range of 100 to 1 10 Cycle/12 Cycle IRMS, VRMS1 0.2 % Data sourced before HPF, no dc offset at inputs, over a dynamic range of 100 to 1 Line Period Measurement 0.001 Hz Resolution at 50 Hz Current to Current, Voltage to Voltage, and Voltage to Current Angle Measurement 0.018 Degrees Resolution at 50 Hz |
类似零件编号 - ADE9000ACPZ-RL |
|
类似说明 - ADE9000ACPZ-RL |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |