8 / 19 page 8 All Avago data sheets report the creepage and clearance inherent to the optocoupler component itself. These di- mensions are needed as a starting point for the equip- ment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit board, mini- mum creepage and clearance requirements must be met as specified for individual equipment standards. For Insulation and Safety Related Specifications Parameter Symbol Value Units Conditions HCPL- 4504 HCPL- J454 -400E/-600E HCPL-J454 All other options HCPL- 0454 HCNW 4504 Minimum External Air Gap (External Clearance) L(101) 7.1 8.0 7.4 4.9 9.6 mm Measured from input ter- minals to output terminals, shortest distance through air. Minimum External Tracking (External Creepage) L(102) 7.4 8.0 8.0 4.8 10.0 mm Measured from input ter- minals to output terminals, shortest distance path along body. Minimum Internal Plastic Gap (Internal Clearance) 0.08 0.5 0.5 0.08 1.0 mm Through insulation distance, conductor to conductor, usually the direct distance between the photoemitter and photodetector inside the optocoupler cavity. Minimum Internal Tracking (Internal Creepage) NA NA NA NA 4.0 mm Measured from input ter- minals to output terminals, along internal cavity. Tracking Resistance (Comparative Tracking Index) CTI ≥175 ≥175 ≥175 ≥175 ≥200 Volts DIN IEC 112/VDE 0303 Part 1 Isolation Group IIIa IIIa IIIa IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1) creepage, the shortest distance path along the surface of a printed circuit board between the solder fillets of the input and output leads must be considered. There are recommended techniques such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and clearances. Creepage and clear- ance distances will also change depending on factors such as pollution degree and insulation level. Regulatory Information The devices contained in this data sheet have been approved by the following agencies: Agency/Standard HCPL-4504 HCPL-J454 HCPL-0454 HCNW4504 Underwriters Laboratories (UL) Recognized under UL1577, Component Recognition Program, Category FPQU2, File E55361 UL1577 3750 Vrms / 1 minute, Option 020 5000 Vrms / 1 minute 3750 Vrms / 1 minute 3750 Vrms / 1 minute 5000 Vrms / 1 minute Canadian Standards Association (CSA) File CA88324 Component Acceptance Notice #5 3750 Vrms / 1 minute, Option 020 5000 Vrms / 1 minute 3750 Vrms / 1 minute 3750 Vrms / 1 minute 5000 Vrms / 1 minute IEC/EN/DIN EN 60747-5-2 Approved under: IEC 60747-5-2:1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01 Option 060 VIORM = 630 Vpeak VIORM = 891 Vpeak Option 060 VIORM = 560 Vpeak VIORM = 1414 Vpeak |
类似零件编号 - HCPL-4504 |
|
类似说明 - HCPL-4504 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |