数据搜索系统,热门电子元器件搜索 |
|
ML100.105 数据表(PDF) 2 Page - Red Lion Controls. Inc |
|
ML100.105 数据表(HTML) 2 Page - Red Lion Controls. Inc |
2 / 2 page 0 8 16 24 32 40 48 56 64 0 1 2 3 4 5 Output current Iout [A] X Input Input voltage AC 100-120/220-240V (Auto Select), 47...63 Hz (AC 85...132V / AC 184...264V, DC 220...375V, N= + and L= - ) Input current <2.1A (@ AC 100Vin, 100W Pout) <1A (@ AC 220Vin, 100W Pout) External fusing not required, unit provides internal fuse (T3A15H, not accessible) Transient immunity Transient resistance acc. to VDE 0160 / W2 (750V/ 1.3 ms), over entire load range Hold-up time (see diagram below) >40 ms @ AC 230V, 48V / 2.1A >20 ms @ AC 196V, 48V / 2.1A >20 ms @ AC 100V, 48V / 2.1A X Efficiency, Reliability Efficiency Losses typ. 91% (AC 230V, 48V / 2.1A) (see also diagram below) typ. 10W (AC 230V, 48V / 2.1A) MTBF (Reliability) appr. 500.000 h acc. to Siemensnorm SN 29500 48V / 2.1A, AC 230V, Tamb = +40 °C) Prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure: • Run-in / burn-in (Full load, Tamb = +60°C, on/off cycle) • Functional test (100 %) X Construction, Mechanics, Installation Robust plastic housing (US Patent No. D442, 923S), fine ventilation grid on three housing sides to keep out small parts (e.g. screws), IP20 Dimensions and weight • W x H x D • Weight 73 mm x 75 mm x 103 mm (+ DIN rail) Depth incl. terminals: 98 mm (+ DIN rail) 360 g Mounting orientation , or (cf. ’Output’) Ventilation/Cooling • Free space f. cooling Normal convection, no fan required recom’d.: 25mm on sides with ventilation grid Easy snap-on mounting onto the DIN-rail (TS35/7,5 or TS35/15). Unit sits safely and firmly on the rail; no tools required even to remove Connection by Spring Clamp terminals; uniformly firm hold, vibration-resistant and maintenance-free: 2 terminals per output Connector size range • flexible cable • solid cable • Wire strip length 0.3-2.5mm2 (28-12 AWG) 0.3-4mm2 (28-12 AWG) Ferrules admissible 6mm (0.24in) recommended Design details – for your advantage: • All terminals are easy to reach as mounted on the front panel. • Input and output are strictly apart from each other (input below, out- put above) and so cannot be mixed up. • Mounting and connection do not require any screwdriver → Easy, quick, durable and reliable installation. X Diagrams 83 84 85 86 87 88 89 90 91 92 93 0,5 0,75 1 1,25 1,5 1,75 2 2,1 Output current Iout [A] 230 VACin 115 VACin 0 20 40 60 80 100 120 -10 0 10 20 30 40 50 60 70 Ambient temperature [°C] 0 20 40 60 80 100 120 140 160 80 120 160 200 240 280 Input voltage VACin [V] Pout=100W, typ. Pout=100W, min. Pout=50W, typ. Pout=50W, min. Output characteristic Vout/Iout (min.) Efficiency Hold-up time with ACin (@ Vout = 48V, typ.) (at Vout = 48V, typ. + min.) Derating of output power Mounting 85-132 V ACin A-a A-b A-b 185-264 V ACin A-a A-b A-b 220-375 V DCin A-a A-b A-b a b A X Output Output voltage • preset DC 48-56V (adj. by front panel potentiometer) 48V ± 0.5% @ 2.1A Voltage regulation stat. <1% Vout (Jumper in pos. 'Single Use') stat. <3% Vout (Jumper in pos. 'Parallel Use'), dyn. ±1.5% Vout over all Ripple/Noise <50mVPP (20 MHz bandw., 50 Ω measurem.) Overvoltage prot. (OVP) <60V Rated continuous loading up to 2.1A @ 48V / 1.8A @ 56V (convection cool- ing), depending on built-in orientation, Vin and Tamb For details see derating diagram below Overload behaviour PULS Overload Design™: No switch-off at overload/short-circuit, instead: up to 1.9 ⋅ Irated. So you need no oversizing to start awkward loads. Protection Unit is protected against (also permanent) short- circuit, overload and open-circuit. Derating depending on built-in orientation; see diagram below Parallel operation yes (selectable by front panel jumper) Power back immunity 63V Operating indicator Green LED X Environmental Data, EMC, Safety Ambient temperature range (measured 25 mm below unit) • storage/transport • operation -25°C ... +85°C -10°C ... +70°C (for derating see diagram below) Humidity max. 95% (without condensation) Electromagnetic emissions (EME) EN 61000-6-3 (includes EN 61000-6-4) Class B (EN 55011, EN 55022) EN 61000-3-2 (PFC) Electromagnetic immunity (EMI) EN 61000-6-2 (includes EN 61000-6-1) Safe low voltage: Prot. class/degree: SELV (EN 60950, VDE0100/T.410), PELV (EN 50178) Class 1 (EN 60950) / IP20 (EN 60529) This unit fulfills all major safety approvals for EU (EN 60 950, EN 60204- 1, EN 50178), USA (UL 60950, E137006, UL508 LISTED, E198865), Canada (CAN/CSA-C22.2 No 60950 [CUR], CAN/CSA-C22.2 No. 14 [CUL]), CB Scheme (IEC 60950). Technical Data ML100.105 Product information (ML100e105), Rev.: 4. May 2004. Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice. PULS GmbH, Arabellastraße 15, D-81925 München X Tel: +49.(0)89.9278-244, Fax: +49.(0)89.9278-199, E-Mail: sales@puls-power.com X www.puls-power.com Spri ng C lam ps Vin = AC 115/230V Vin = AC 115/230V 'Single Use' 'Parallel Use' |
类似说明 - ML100.105 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |