数据搜索系统,热门电子元器件搜索 |
|
TDA8024 数据表(PDF) 8 Page - NXP Semiconductors |
|
TDA8024 数据表(HTML) 8 Page - NXP Semiconductors |
8 / 29 page 2004 July 12 8 Philips Semiconductors Product specification IC card interface TDA8024 8 FUNCTIONAL DESCRIPTION Throughout this document it is assumed that the reader is familiar with ISO7816 terminology. 8.1 Power supply The supply pins for the IC are VDD and GND. VDD should be in the range of 2.7 to 6.5 V. All signals interfacing with the system controller are referred to VDD, therefore VDD should also supply the system controller. All card reader contacts remain inactive during power-on or power-off. The internal circuits are maintained in the reset state until VDD reaches Vth2 +Vhys2 and for the duration of the internal Power-on reset pulse, tW (see Fig.5). When VDD falls below Vth2, an automatic deactivation of the contacts is performed. A DC/DC converter is incorporated to generate the 5 or 3 V card supply voltage (VCC). The DC/DC converter should be supplied separately by VDDP and PGND. Due to the possibility of large transient currents, the two 100 nF capacitors of the DC/DC converter should be located as near as possible to the IC and have an ESR less than 100 m Ω. The DC/DC converter functions as a voltage doubler or a voltage follower according to the respective values of VCC and VDDP (both have thresholds with a hysteresis of 100 mV). The DC/DC converter function changes as follows: • VCC = 5 V and VDDP > 5.8 V; voltage follower • VCC = 5 V and VDDP < 5.7 V; voltage doubler • VCC = 3 V and VDDP > 4.1 V; voltage follower • VCC = 3 V and VDDP < 4.0 V; voltage doubler. Supply voltages VDD and VDDP may be applied to the IC in any sequence. After powering the device, OFF remains LOW until CMDVCC is set HIGH. During power off, OFF falls LOW when VDD is below the falling threshold voltage. 8.2 Voltage supervisor 8.2.1 WITHOUT EXTERNAL DIVIDER ON PIN PORADJ (OR WITH TDA8024AT) The voltage supervisor surveys the VDD supply. A defined reset pulse of approximately 8 ms (tW) is used internally to keep the IC inactive during power-on or power-off of the VDD supply (see Fig.5). As long as VDD is less than Vth2 +Vhys2, the IC remains inactive whatever the levels on the command lines. This state also lasts for the duration of tW after VDD has reached a level higher than Vth2 +Vhys2. When VDD falls below Vth2, a deactivation sequence of the contacts is performed. handbook, full pagewidth Vth2 + Vhys2 VDD Vth2 ALARM (internal signal) supply dropout power-off power-on MDB053 tw tw Fig.5 Voltage supervisor. |
类似零件编号 - TDA8024 |
|
类似说明 - TDA8024 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |