数据搜索系统,热门电子元器件搜索 |
|
93C76-SN 数据表(PDF) 9 Page - Microchip Technology |
|
93C76-SN 数据表(HTML) 9 Page - Microchip Technology |
9 / 12 page © 1996 Microchip Technology Inc. Preliminary DS21132C-page 9 93C76/86 FIGURE 3-8: ERAL Guarantee at VCC = +4.5V to +5.5V. ORG=VCC, 8 X’s ORG=VSS, 9 X’s 10 01 0 X X ... CS CLK DI DO TEC TCZ HIGH IMPEDANCE BUSY READY STANDBY 4.0 PIN DESCRIPTIONS 4.1 Chip Select (CS) A HIGH level selects the device. A LOW level deselects the device and forces it into standby mode. However, a programming cycle which is already initiated will be completed, regardless of the CS input signal. If CS is brought LOW during a program cycle, the device will go into standby mode as soon as the programming cycle is completed. CS must be LOW for 250 ns minimum (TCSL) between consecutive instructions. If CS is LOW, the internal con- trol logic is held in a RESET status. 4.2 Serial Clock (CLK) The Serial Clock is used to synchronize the communi- cation between a master device and the 93C76/86. Opcode, address, and data bits are clocked in on the positive edge of CLK. Data bits are also clocked out on the positive edge of CLK. CLK can be stopped anywhere in the transmission sequence (at HIGH or LOW level) and can be continued anytime with respect to clock HIGH time (TCKH) and clock LOW time (TCKL). This gives the controlling mas- ter freedom in preparing opcode, address, and data. CLK is a “Don't Care” if CS is LOW (device deselected). If CS is HIGH, but START condition has not been detected, any number of clock cycles can be received by the device without changing its status (i.e., waiting for START condition). CLK cycles are not required during the self-timed WRITE (i.e., auto ERASE/WRITE) cycle. After detection of a start condition the specified number of clock cycles (respectively LOW to HIGH transitions of CLK) must be provided. These clock cycles are required to clock in all opcode, address, and data bits before an instruction is executed (see Table 1-4 through Table 1-7 for more details). CLK and DI then become don't care inputs waiting for a new start condition to be detected. 4.3 Data In (DI) Data In is used to clock in a START bit, opcode, address, and data synchronously with the CLK input. 4.4 Data Out (DO) Data Out is used in the READ mode to output data syn- chronously with the CLK input (TPD after the positive edge of CLK). This pin also provides READY/BUSY status information during ERASE and WRITE cycles. READY/BUSY sta- tus information is available when CS is high. It will be displayed until the next start bit occurs as long as CS stays high. 4.5 Organization (ORG) When ORG is connected to VCC, the x16 memory orga- nization is selected. When ORG is tied to VSS, the x8 memory organization is selected. There is an internal pull-up resistor on the ORG pin that will select x16 orga- nization when left unconnected. 4.6 Program Enable (PE) This pin allows the user to enable or disable the ability to write data to the memory array. If the PE pin is floated or tied to VCC, the device can be programmed. If the PE pin is tied to VSS, programming will be inhib- ited. There is an internal pull-up on this device that enables programming if this pin is left floating. Note: CS must go LOW between consecutive instructions, except when performing a sequential read (Refer to Section 3.1 for more detail on sequential reads). |
类似零件编号 - 93C76-SN |
|
类似说明 - 93C76-SN |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |