ISL29038IROZ-EVALZ 数据表(PDF) 11 Page - Intersil Corporation

部件名 ISL29038IROZ-EVALZ
功能描述  Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
Download  15 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  INTERSIL [Intersil Corporation]
网页  http://www.intersil.com/cda/home
标志 INTERSIL - Intersil Corporation

ISL29038IROZ-EVALZ 数据表(HTML) 11 Page - Intersil Corporation

Back Button ISL29038IROZ-EVALZ Datasheet HTML 7Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 8Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 9Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 10Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 11Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 12Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 13Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 14Page - Intersil Corporation ISL29038IROZ-EVALZ Datasheet HTML 15Page - Intersil Corporation  
Zoom Inzoom in Zoom Outzoom out
 11 / 15 page
background image
ISL29038
11
FN7851.1
January 23, 2015
Submit Document Feedback
ALS IR Compensation
The ISL29038 is designed for operation under dark glass cover.
Glass or plastic covers can significantly attenuate visible light
and pass the Infrared light without much attenuation.
Consequently, the ISL29038 under a glass cover experiences an
IR rich environment.
The on-chip ALS passive optical filter on the ISL29038 is designed
to block most of the IR incident on the ALS photo diodes. In
addition, the ISL29038 provides a programmable active IR
compensation that subtracts residual IR still reaching the sensor.
The ALS_IR_COMP register (Reg 0x03[4:0]) allows fine tuning of
the residual infrared component from the ALS output.
The recommended procedure for determining ALS IR
compensation is as follows:
• Illuminate the ISL29038 based product with a light source
without IR, such as a white LED. Record the ALS measurement
and the Lux level.
• Illuminate the device with an IR LED and the White LED. Take
an ALS measurement and Lux level measurement.
• Adjust the ALS_IR_COMP register (Reg 0x03, bits 4:0) to
compensate for the IR contribution.
• Repeat steps above until the IR light source contribution to the
ALS measurement is under 10 percent assuming no change in
Lux level due to IR light source.
Proximity Offset
Systems built with a protective glass cover over the ISL29038
can provide light ‘leakage’ or ‘crosstalk’ from the IR LED by
reflection from the glass saturating the proximity sensor
measurement system (Figure 11).
Saturation can occur when the reflection from the glass with no
object in the proximity detection space exceeds the full scale of
the measurement system. The ISL29038 proximity system
provides a user programmable proximity offset correction to
compensate for this reflection.
The PROX_IR_COMP register (Reg 0x02[6:3]) applies a corrective
offset to the received signal prior to ADC conversion, which
allows the signal to be brought within the usable range of the
proximity measurement system.
Proximity Ambient Washout Detection
Optical proximity sensor can saturate when illuminated with
excessive ambient light. The ISL29038 provides a warning flag
when the proximity measurement may be erroneous due to
excessive ambient light. The PROX_WASH register (Reg 0x0D[0])
reports this condition.
Interrupts Events
The ISL29038 interrupts are designed to minimize host
microcontroller overhead of continuous polling. The ISL29038
can generate interrupts on the results of an ALS measurement or
proximity measurement.
The ALS interrupt event ALS_FLAG (Reg 0x04[3]) is governed by
Reg 0x07 through 0x09. Two-12 bit high and low threshold
values are written to these registers. The ISL29038 will set the
ALS interrupt flag if the ADC conversion count in Registers 0x0B
and 0x0C are outside the programmed thresholds. The
ALS_FLAG is cleared by writing a ‘0’ to Reg 0x04[3].
A proximity interrupt event (PROX_FLAG) is governed by the high
and low thresholds in Reg 0x05 and 0x06 (PROX_LT and
PROX_HT) and is indicated by Reg 0x04[7]. PROX_FLAG is set
when the measured proximity data is more than the higher
threshold. The proximity interrupt flag is cleared when the
proximity data is lower than the low proximity threshold or by
writing a ‘0’ to Reg 0x04[7].
The Proximity interrupt generation can be selected between
‘out-of-window’ threshold and hysteresis schemes. When the
PROX_INT_ALG register (Reg 0x02, Bit 7) is set to 0, proximity
uses a window comparator scheme; when set to 1, proximity
uses a hysteresis scheme.
In hysteresis mode, the interrupt event is generated if the
proximity ADC count is higher than the PROX_HT threshold and
the interrupt event is cleared when the proximity ADC count is
less than the PROX_LT threshold. The interrupt event flag can
also be cleared by writing a ‘0’ to Reg 0x04[7].
INTERRUPT PERSISTENCE
To minimize interrupt events due to ‘transient’ conditions, an
interrupt persistency option is available for both ALS and proximity
measurements. Persistency requires ‘X-consecutive’ interrupt flags
before the INT pin is driven low. Both ALS and PROX have their own
independent interrupt persistency options. ALS_PRST and
PROX_PRST configuration are controlled from Reg 0x04.
Power-Up and ‘Brown-Out’ Reset
The ISL29038 has an enhanced power-on-reset system. A
‘Brown-Out’ detector flag in Reg 0x04[4] informs the system that
the device has powered-up properly. This flag should be reset as
part of the initialization sequence.
A ‘Brown-Out’ condition is defined as an operating condition
when the power supply voltage is not within the specified limits.
During the brown-out period at power-up, the I2C interface and
the IR LED driver are inactive. Following brown-out, the I2C
interface is re-initialized and the configuration registers are set to
power-up default values. After power-up and during device
initialization, host should examine that the PWR_FAIL flag
FIGURE 11. PROXIMITY SET-UP HIGHLIGHTING CROSSTALK
REFLECTED FROM COVER GLASS
LED
SENSOR
PCB
GLASS COVER


类似零件编号 - ISL29038IROZ-EVALZ

制造商部件名数据表功能描述
logo
Xicor Inc.
ISL29038IROZ-EVALZ XICOR-ISL29038IROZ-EVALZ Datasheet
560Kb / 15P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
logo
Renesas Technology Corp
ISL29038IROZ-EVALZ RENESAS-ISL29038IROZ-EVALZ Datasheet
729Kb / 15P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
More results

类似说明 - ISL29038IROZ-EVALZ

制造商部件名数据表功能描述
logo
Xicor Inc.
ISL29038 XICOR-ISL29038 Datasheet
560Kb / 15P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
logo
Renesas Technology Corp
ISL29038 RENESAS-ISL29038 Datasheet
729Kb / 15P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
ISL29147 RENESAS-ISL29147 Datasheet
711Kb / 15P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
logo
Intersil Corporation
ISL29147 INTERSIL-ISL29147 Datasheet
126Kb / 2P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
ISL29147IROMZ-T7 INTERSIL-ISL29147IROMZ-T7 Datasheet
413Kb / 15P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
January 6, 2015
ISL29038 INTERSIL-ISL29038 Datasheet
186Kb / 2P
   Low Power Ambient Light and Proximity Sensor with Enhanced Infrared Rejection
logo
Maxim Integrated Produc...
MAX44000 MAXIM-MAX44000 Datasheet
1Mb / 24P
   Ambient and Infrared Proximity Sensor
Rev 0; 10/11
logo
Intersil Corporation
ISL29029 INTERSIL-ISL29029 Datasheet
761Kb / 16P
   Low Power Ambient Light and Proximity Sensor with Intelligent Interrupt
ISL29028 INTERSIL-ISL29028 Datasheet
466Kb / 15P
   Low Power Ambient Light and Proximity Sensor with Intelligent Interrupt
logo
OSRAM GmbH
SFH7771 OSRAM-SFH7771 Datasheet
1Mb / 30P
   Ambient Light and Proximity Sensor
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15


数据表 下载

Go To PDF Page


链接网址




隐私政策
ALLDATASHEETCN.COM
ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com