数据搜索系统,热门电子元器件搜索 |
|
CXA-0474 数据表(PDF) 1 Page - TDK Electronics |
|
CXA-0474 数据表(HTML) 1 Page - TDK Electronics |
1 / 4 page ■ Features CXA-0474 Dimming/Connector Type CXA-0474 Specifications(Please refer to each specification before use) ■ Applications ●2-output ●Applicable panel size*: 10 to 12 inches ●With brightness control function (Pulse Wide Modulation mode). ●With shut down function. ●With a sensing function for running out of lamp (alarm output). ●In the high-voltage generator(a terminal and a pattern), an anti-dust measure by silicone application is taken. (Notice) Applicable panel size becomes a standard. Electrical Characteristics Other Specifications Item Unit Symbol Specification Condition min typ max Vin(V) Vrmt(V) Vbr(V) Rbr(kΩ ) Ta(℃ ) RL(kΩ ) Remark Output Current mArms Iout (Maximum dimmer) 4.5 5.0 5.5 12 0.6 5 2.5 - -10 to +70 110 Voltage dimmer (*1) 4.5 5.0 5.5 12 0.6 5 - 10 -10 to +70 110 Volume dimmer (*1) Iout (Minimum dimmer) 1.5 2.5 3.5 12 0.6 5 0 - -10 to +70 110 Voltage dimmer (*1) 1.5 2.5 3.5 12 0.6 5 - 0 -10 to +70 110 Volume dimmer (*1) Input Current AIin1 - 0.6 1.0 12 0.6 5 2.5 10 -10 to +70 110 Remote ON mA Iin2 - 1 12 0.6 0 2.5 10 -10 to +70 110 Remote OFF Frequency kHz Freq1 63.5 67.5 72.0 12 0.6 5 2.5 10 -10 to +70 110 Hz Freq2 (Duty frequency) 241 255 268 12 0.6 5 0 -10 to +70 110 Open Circuit Voltage Vrms Vopen 1750 1850 1950 11.4min. 5 2.5 10 -10 to +70 ∞ Open load Alarm Signal V Vst 4.5 5 5.5 12 0.6 5 2.5 10 -10 to +70 ∞ In case of lamp anomaly (*2) - 0 0.5 12 0.6 5 2.5 10 -10 to +70 110 On a normal operation (*2) (*1) Please refer to the connection diagram for details of a dimming method. (*2) Please refer to the connection diagram for details of alarm output. Dimming Function Yes Operating Temperature ℃ -10 to +70 Storage Temperature ℃ -30 to +85 Operating Humidity Ratio RH% 95Max Safety Standard ー Weight g 22 Dimensions(WxDxH) mm 114x25x8.5 (*3) Fused Input Yes Remote ON / OFF Yes Alarm Signal Function Yes Shutdown Function Yes Silicone Coating on High Voltage Area Yes (*3) These dimensions are indicated the maximum only H. Others are typical values. This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. ■ Conformity to RoHs Directive ・All specifications are subject to change without notice. 1 001-01/20080228/etl_cxa_0474 |
类似零件编号 - CXA-0474 |
|
类似说明 - CXA-0474 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |