数据搜索系统,热门电子元器件搜索 |
|
CS5165GDWR16 数据表(PDF) 9 Page - Cherry Semiconductor Corporation |
|
CS5165GDWR16 数据表(HTML) 9 Page - Cherry Semiconductor Corporation |
9 / 19 page Figure 5: Normal Operation showing Output Inductor Ripple Current and Output Voltage Ripple, 0.5A Load, VOUT = +2.84V (DAC = 10111) Figure 6: Normal Operation showing Output Inductor Ripple Current and Output Voltage Ripple, ILOAD = 14A, VOUT = +2.84V (DAC = 10111) Transient Response The CS5165 V2™ Control Loop’s 100ns reaction time pro- vides unprecedented transient response to changes in input voltage or output current. Pulse-by-pulse adjustment of duty cycle is provided to quickly ramp the inductor cur- rent to the required level. Since the inductor current cannot be changed instantaneously, regulation is maintained by the output capacitor(s) during the time required to slew the inductor current. Overall load transient response is further improved through a feature called “Adaptive Voltage Positioning”. This technique pre-positions the output capacitors voltage to reduce total output voltage excursions during changes in load. Holding tolerance to 1% allows the error amplifiers refer- ence voltage to be targeted +40mV high without compro- mising DC accuracy. A “Droop Resistor”, implemented through a PC board trace, connects the Error Amps feed- back pin (VFB) to the output capacitors and load and carries the output current. With no load, there is no DC drop across this resistor, producing an output voltage tracking the Error amps, including the +40mV offset. When the full load current is delivered, an 80mV drop is developed across this resistor. This results in output voltage being off- set -40mV low. The result of Adaptive Voltage Positioning is that addition- al margin is provided for a load transient before reaching the output voltage specification limits. When load current suddenly increases from its minimum level, the output capacitor is pre-positioned +40mV. Conversely, when load current suddenly decreases from its maximum level, the output capacitor is pre-positioned -40mV (see figures 7, 8, and 9). For best Transient Response, a combination of a number of high frequency and bulk output capacitors are usually used. If the Maximum On-Time is exceeded while responding to a sudden increase in Load current, a normal off-time occurs to prevent saturation of the output inductor. Figure 7: Output Voltage Transient Response to a 14A load pulse, VOUT= +2.84V (DAC = 10111). Trace 3 -Load Current (5A/10mV/div) Trace 4 - VOUT (100mV/div) Trace 1 - GATE(H) (10/div) Trace 2 - Inductor Switching Node (5V/div) Trace 3 - Output Inductor Ripple Current (2A/div) Trace 4 - VOUT ripple (20mV/div) Trace 1 GATE (H) (10V/div) Trace 2 Inductor Switching Node (5V/div) Trace 3 Output Inductor Ripple Current (2A/div) Trace 4 VOUT ripple (20mV/div) 9 Application Information: continued |
类似零件编号 - CS5165GDWR16 |
|
类似说明 - CS5165GDWR16 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |