数据搜索系统,热门电子元器件搜索 |
|
3UG4512 数据表(PDF) 10 Page - List of Unclassifed Manufacturers |
|
3UG4512 数据表(HTML) 10 Page - List of Unclassifed Manufacturers |
10 / 114 page SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF7 motor management and control devices 7/10 Siemens LV 1 T · 2006 Expansion with additional inputs/outputs by means of an analog module Basic unit 2 can be optionally expanded with analog inputs and outputs (0/4 ... 20 mA) by means of the analog module. It is then possible to measure and monitor any process variable that can be mapped on a 0/4 ... 20 mA signal. Typical applications are, for example, level monitoring for the implementation of dry run- ning protection for pumps or monitoring the degree of pollution of a filter using a differential pressure transducer. In this case the automation system has free access to the measured process variables. The analog output can be used, for example, to visu- alize process variables on a pointer instrument. The automation system also has free access to the output. Maximum one analog module can be connected to one basic unit 2. Both inputs are set to a measuring range of either 0 ... 20 mA or 4 ... 20 mA. 3UF7 400-1AA00-0 analog module Inputs: • 2 inputs for measuring 0/4 ... 20 mA signals Outputs: • 1 output to output a 0/4 ... 20 mA signal 1 Ready LED 2 system interfaces for connection • To basic unit 2 • Of expansion modules • Of a current measuring module or current/voltage measuring module • Of an operator panel Note: An analog module can only be used with a basic unit 2, product version E02 and later (from April 2005). Safe isolation All circuits in SIMOCODE pro are safely isolated from each other in according to IEC 60947-1. That is, they are designed with double creepage and air distances. In the event of a fault, therefore, no parasitic voltages can be formed in neighboring circuits. The instructions of test report No. 2668 must be complied with. EEx e and EEx d types of protection The overload protection and the thermistor motor protection of the SIMOCODE pro system comply with the requirements for overload protection of explosion-protected motors to the degree of protection: • EEx d "flameproof enclosure" e.g. according to EN 50018 or EN 60079-1 • EEx e "increased safety" e.g. according to EN 50019 or EN 60079-7 When using SIMOCODE pro devices with a 24 V DC control voltage, electrical isolation must be ensured using a battery or a safety transformer according to EN 61558-2-6. EC type test certificate: BVS 04 ATEX F 003 Test log: BVS PP 05.2029 EG. |
类似零件编号 - 3UG4512 |
|
类似说明 - 3UG4512 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |