SA2007MSA 数据表(PDF) 7 Page - Sames

部件名 SA2007MSA
功能描述  Single Phase Power/Energy Metering IC with Tamper Detection
Download  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  SAMES [Sames]
网页  http://www.sames.co.za
标志 SAMES - Sames

SA2007MSA 数据表(HTML) 7 Page - Sames

Back Button SA2007MSA Datasheet HTML 2Page - Sames SA2007MSA Datasheet HTML 3Page - Sames SA2007MSA Datasheet HTML 4Page - Sames SA2007MSA Datasheet HTML 5Page - Sames SA2007MSA Datasheet HTML 6Page - Sames SA2007MSA Datasheet HTML 7Page - Sames SA2007MSA Datasheet HTML 8Page - Sames SA2007MSA Datasheet HTML 9Page - Sames SA2007MSA Datasheet HTML 10Page - Sames  
Zoom Inzoom in Zoom Outzoom out
 7 / 10 page
background image
sames
sames
SA2007M
7/10
http://www.sames.co.za
TYPICAL APPLICATION
The analog (metering) interface described in this section is
designed for measuring 230V/60A with precision better than
Class 1.
The most important external components for the SA2007M
integrated circuit are the current sense resistors, the voltage
sense resistors and the bias setting resistor. The resistors
used in the metering section should be of the same type so
temperature effects are minimized.
Current Input IIN1, IIP1, IIN2, IIP2
Two current transformers are used to measure the current in
the live and neutral phases. The output of the current
transformer is terminated with a low impedance resistor. The
voltage drop across the termination resistor is converted to a
current that is fed to the differential current inputs of the
SA2007M.
CT Termination Resistor
The voltage drop across the CT termination resistor at rated
current should be at least 20mV. The CTs have low phase shift
and a ratio of 1:2500. The CT is terminated with a 3.6W resistor
giving a voltage drop of 86.4mV across the termination resistor
at rated conditions (I
for the meter).
max
The termination resistor on the second current channel is
adjustable by means of P2 to facilitate channel equalization
calibration. The termination resistor is chosen so that a 10W
trimpot in parallel will provide a sufficient channel range.
Current Sensor Input Resistors
The resistors R10, R11 and R12, R13 define the current level
into the current sense inputs of the SA2007M. The resistor
values are selected for an input current of 16µA on the current
inputs of the SA2007M at rated conditions. For a 60A meter at
2500:1 CT the resistor values are calculated as follows:
R10 = R11 = ( I / 16µA ) x R / 2
LSH
= 60A / 2500 / 16µA x 3.6W / 2
= 2.7kW
I = Line current
L
RSH = CT Termination resistor
2500 = CT ratio
The two current channels are identical so R10 = R11 = R12 =
R13.
Voltage Input IVP
The voltage input of the SA2007M (IVP) is driven with a current
of 14µA at nominal mains voltage. The voltage input saturates
at approximately 17µA. At a nominal voltage current of 14µA
allows for 20% overdriving. The mains voltage is divided with a
voltage divider to 14V that is fed to the voltage input pins via a
1MW resistor.
Voltage Divider
The voltage divider is calculated for a voltage drop of 14V.
Equations for the voltage divider are:
RA = R1 + R2 + R3
RB = R7 || (R5 + P1)
A 5k trimpot will be used in the voltage channel for meter
calibration. The center position on the pot is used in the
calibration P1 = 2.5kW.
Combining the two equations gives:
( RA + RB ) / 230V = RB / 14V
Values for resistors R5 = 22kW, P1 = 2.5kW and R7 = 1M W is
chosen.
Substituting the values result in:
RB = 23.9kW
RA = RB x ( 230V / 14V – 1 )
RA = 369kW.
Standard resistor values of R1, R2 and R3 are chosen to be
120kW, 120kW and 130kW.
The capacitor C1 is used to compensate for phase shift
between the voltage sense inputs and the current sense inputs
of the device, in cases where CTs with phase errors are used.
The phase shift caused by the CT may be corrected by
inserting a capacitor in the voltage divider circuit. To
compensate for a phase shift of 0.18 degrees the capacitor
value is calculated as follows:
C = 1 / (2 x p x Mains frequency x R5 x tan (Phase shift angle))
C = 1 / ( 2 x p x 50 x 1MW x tan (0.18 degrees ))
C = 1.013µF
Reference Voltage Bias resistor
R6 defines all on chip and reference currents. With R6 = 24kW
optimum conditions are set. Device calibration is done on the
voltage input of the device.
PRELIMINARY


类似零件编号 - SA2007MSA

制造商部件名数据表功能描述
logo
Sames
SA2007H SAMES-SA2007H Datasheet
154Kb / 10P
   Single Phase Bidirectional Dual Element Power/Energy Metering IC with Pulse Output
SA2007HPA SAMES-SA2007HPA Datasheet
154Kb / 10P
   Single Phase Bidirectional Dual Element Power/Energy Metering IC with Pulse Output
SA2007HSA SAMES-SA2007HSA Datasheet
154Kb / 10P
   Single Phase Bidirectional Dual Element Power/Energy Metering IC with Pulse Output
SA2007P SAMES-SA2007P Datasheet
138Kb / 12P
   Programmable Single Phase Energy Metering IC with Tamper Detection
SA2007PPA SAMES-SA2007PPA Datasheet
138Kb / 12P
   Programmable Single Phase Energy Metering IC with Tamper Detection
More results

类似说明 - SA2007MSA

制造商部件名数据表功能描述
logo
Sames
SA9607M SAMES-SA9607M Datasheet
98Kb / 10P
   Single Phase Power/Energy Metering IC with Tamper Detection
logo
STMicroelectronics
STPM01 STMICROELECTRONICS-STPM01_11 Datasheet
1Mb / 60P
   Programmable single phase energy metering IC with tamper detection
logo
Sames
SA9607P SAMES-SA9607P Datasheet
127Kb / 12P
   Programmable Single Phase Energy Metering IC with Tamper Detection
logo
List of Unclassifed Man...
STPM01 ETC-STPM01 Datasheet
137Kb / 9P
   PROGRAMMABLE SINGLE PHASE ENERGY METERING IC WITH TAMPER DETECTION
logo
STMicroelectronics
STPM10 STMICROELECTRONICS-STPM10_V01 Datasheet
1Mb / 47P
   Programmable single-phase energy metering IC with tamper detection
February 2017
logo
Sames
SA2007P SAMES-SA2007P Datasheet
138Kb / 12P
   Programmable Single Phase Energy Metering IC with Tamper Detection
logo
STMicroelectronics
STPM10 STMICROELECTRONICS-STPM10 Datasheet
1Mb / 51P
   Programmable single-phase energy metering IC with tamper detection
logo
ATMEL Corporation
AVR465 ATMEL-AVR465 Datasheet
305Kb / 40P
   Single-Phase Power/Energy Meter with Tamper Detection
logo
STMicroelectronics
AN2288 STMICROELECTRONICS-AN2288 Datasheet
247Kb / 29P
   Single-phase energy meter with tamper detection based on ST7FLITE2x
STPM01 STMICROELECTRONICS-STPM01 Datasheet
775Kb / 56P
   Programmable single phase energy metering IC
More results


Html Pages

1 2 3 4 5 6 7 8 9 10


数据表 下载

Go To PDF Page


链接网址




隐私政策
ALLDATASHEETCN.COM
ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com