数据搜索系统,热门电子元器件搜索 |
|
M41T0M6E 数据表(PDF) 10 Page - STMicroelectronics |
|
M41T0M6E 数据表(HTML) 10 Page - STMicroelectronics |
10 / 22 page Operation M41T0 10/22 2.2 READ mode In this mode, the master reads the M41T0 slave after setting the slave address (see Figure 7). Following the WRITE mode control bit (R/W = 0) and the acknowledge bit, the word address An is written to the on-chip address pointer. Next the START condition and slave address are repeated, followed by the READ mode control bit (R/W = 1). At this point, the master transmitter becomes the master receiver. The data byte which was addressed will be transmitted and the master receiver will send an acknowledge bit to the slave transmitter. The address pointer is only incremented on reception of an acknowledge bit. The M41T0 slave transmitter will now place the data byte at address An+1 on the bus. The master receiver reads and acknowledges the new byte and the address pointer is incremented to An+2. This cycle of reading consecutive addresses will continue until the master receiver sends a STOP condition to the slave transmitter. An alternate READ mode may also be implemented, whereby the master reads the M41T0 slave without first writing to the (volatile) address pointer. The first address that is read is the last one stored in the pointer (see Figure 9 on page 12). Table 2. AC characteristics Symbol Parameter(1) 1. Valid for ambient operating temperature: TA = –40 to 85°C; VCC = 2.0 to 5.5 V (except where noted). Min Typ Max Unit fSCL SCL clock frequency 0 400 kHz tLOW Clock low period 1.3 µs tHIGH Clock high period 600 ns tR SDA and SCL rise time 300 ns tF SDA and SCL fall time 300 ns tHD:STA START condition hold time (after this period the first clock pulse is generated) 600 ns tSU:STA START condition setup time (only relevant for a repeated start condition) 600 ns tSU:DAT Data setup time 100 ns tHD:DAT (2) 2. Transmitter must internally provide a hold time to bridge the undefined region (300 ns max.) of the falling edge of SCL. Data hold time 0 µs tSU:STO STOP condition setup time 600 ns tBUF Time the bus must be free before a new transmission can start 1.3 µs |
类似零件编号 - M41T0M6E |
|
类似说明 - M41T0M6E |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |