3 / 5 page Nominal Output Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Output Receptacles Hardwire Individually Controllable Load Banks No INPUT Rated input current (Maximum Load) 93.2A Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G) UPS Input Connection Type Hardwire Input Circuit Breakers 125A (3 pole) Input Phase 3-Phase Power Factor (Input) .99PF (100% load) THDi <3% (100% load) BATTERY Expandable Battery Runtime Supports extended runtime with optional external battery packs. Please consult the owners manual. External Battery Pack Compatibility <a class="productLink" href="//www.tripplite.com/external-ups-battery-pack-40-100-Ah- battery~BP480V100">BP480V100</a> ; <a class="productLink" href="//www.tripplite.com/external- ups-battery-pack-40-100-Ah-battery~BP480V100">BP480V100</a> -NIB; <a class="productLink" href="//www.tripplite.com/external-ups-battery-pack-40-40-Ah-battery~BP480V40">BP480V40</a> ; <a class="productLink" href="//www.tripplite.com/external-ups-battery-pack-40-40-Ah- battery~BP480V40">BP480V40</a> -NIB; <a class="productLink" href="//www.tripplite.com/external- ups-battery-pack-40-65-Ah-battery~BP480V65">BP480V65</a> DC System Voltage (VDC) +/- 240 Battery Recharge Rate (Included Batteries) 9 hours to 90% (Internal batteries) Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing) Switches ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information) Audible Alarm Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions LED Indicators 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes 3 / 5 |
类似零件编号 - S3M60KXD |
|
类似说明 - S3M60KXD |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |