5 / 22 page www.ti.com Electrical Characteristics for 3.3-V Supply (1) TS5A23166 0.9- Ω DUAL SPST ANALOG SWITCH 5-V/3.3-V 2-CHANNEL ANALOG SWITCH SCDS196 – MAY 2005 V + = 4.5 V to 5.5 V, TA = –40°C to 85°C (unless otherwise noted) PARAMETER SYMBOL TEST CONDITIONS TA V+ MIN TYP MAX UNIT Analog Switch VCOM, Analog signal range 0 V+ V VNO 25 °C 1.3 1.6 0 ≤ V NO ≤ V+, Switch ON, Peak ON resistance rpeak 3 V Ω ICOM = –100 mA, See Figure 13 Full 1.8 25 °C 1.1 1.5 VNO = 2 V, Switch ON, ON-state resistance ron 3 V Ω ICOM = –100 mA, See Figure 13 Full 1.7 ON-state resistance 25 °C 0.04 0.1 VNO = 2 V, 0.8 V, Switch ON, match between ∆r on 3 V Ω ICOM = –100 mA, See Figure 13 Full 0.1 channels 0 ≤ V NO ≤ V+, Switch ON, 25 °C 0.3 ICOM = –100 mA See Figure 13 ON-state resistance ron(flat) 3 V Ω flatness 25 °C 0.15 0.25 VNO = 2 V, 0.8 V, Switch ON, ICOM = –100 mA, See Figure 13 Full 0.25 VNO = 1 V, VCOM = 3 V, 25 °C –5 0.5 5 Switch OFF, INO(OFF) or 3.6 V nA See Figure 14 Full –50 50 NO VNO = 3 V, VCOM = 1 V, OFF leakage current 25 °C –5 0.1 5 VNO = 0 to 3.6 V, Switch OFF, INO(PWROFF) 0 V µA VCOM = 3.6 V to 0, See Figure 14 Full –25 25 VCOM = 1 V, VNO = 3 V, 25 °C –5 0.5 5 Switch OFF, ICOM(OFF) or 3.6 V nA See Figure 14 Full –50 50 COM VCOM = 3 V, VNO = 1 V, OFF leakage current 25 °C –5 0.1 5 VCOM = 0 to 3.6 V, Switch OFF, ICOM(PWROFF) 0 V µA VNO = 3.6 V to 0, See Figure 14 Full –25 25 VNO = 1 V, 25 °C –2 0.3 2 VCOM = Open, NO Switch ON, INO(ON) or 3.6 V nA ON leakage current See Figure 15 Full –20 20 VNO = 3 V, VCOM = Open, VCOM = 1 V, 25 °C –2 0.3 2 VNO = Open, COM Switch ON, ICOM(ON) or 3.6 V nA ON leakage current See Figure 15 Full –20 20 VCOM = 3 V, VNO = Open, Digital Control Inputs (IN1, IN2)(2) Input logic high VIH Full 2 5.5 V Input logic low VIL Full 0 0.8 V 25 °C –2 0.3 2 Input leakage current IIH, IIL VI = 5.5 V or 0 3.6 V nA Full –20 20 (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum (2) All unused digital inputs of the device must be held at V+ or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004. 5 |
类似零件编号 - TS5A23166DCURE4 |
|
类似说明 - TS5A23166DCURE4 |
|
|
链接网址 |
隐私政策 |
ALLDATASHEETCN.COM |
ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |